en_BA_RR30_IO-Link_V0.23.docx
9/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
-
Value of MDC
1000
-
Unit
m
-
Scale
-6
-
Measured value
1000*10
-6
m or 1000
m
Bit 16 to 47: MDC
MDC stands for measurement data channel. It contains the already filtered date arising from SSC1 to SSC4
as an 32 bit integer value. See section 4.2 to learn how to configure the MDC.
Bit 48 to 207 : Peak Data
Peak data is the main measurement data. The values are the first 5 peaks from the defined
Region of
Interest
(all further peaks are ignored) transmitted as two 16 bit values: 16 bit for the amplitude and 16 bit for
the distance. The Amplitude in dB shows the relative strength of the signal and the distance is displayed in
mm.
3.2.2
Process Data-Out
This data is cyclically sent from the master to the sensor (Master
S
ensor).
IO-Link Process Data Output
Bit:
7
6
5
4
3
2
1
0
Find Me (Localization: green
and yellow LED flashing)
Disable Radar
antenna
Bit 0: Disable Radar antenna (Transducer)
By changing this bit the antenna is disabled. This switches off the sensing (receiving) element without switching
off the whole electronic of the sensor. The sensor output will be frozen for all distance and amplitude values.
This can be used to reduce the heating of the sensor itself.
Bit 0 = 0 → Radar antenna is enabled
Bit 0 = 1 → Radar antenna is disabled
Bit 1: Find Me Function
Signaling e.g. by flashing LEDs (green and yellow) on the sensor to locate or physically identify a sensor in a
machine or system.
Bit 1 = 0 → Find Me Function is deactivated
Bit 1 = 1 → Find Me Function is activated, LEDs are flashing.