en_BA_RR30_IO-Link_V0.23.docx
25/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
d
B
Distance (mm)
200
2000
4000
30
20
10
0
Very high
Very low
Medium (Default)
Figure 23: Sensitivity Scale (Example)
4.7.2
Peak Selection Mode
The parameter defines the peak to be chosen for the calculation of the “Measurement Value” in the process
data. The selection relies on the 5 available peaks in process data after using the sensitivity filter. As in most
application the first peak is the desired, on it is the default setting. Please take care that when not operating
the sensor in the Peak Selection mode “First peak” or “Highest Peak“ the risk in receiving a wrong
measurement is increased. If the measurement result is insufficient (e.g. wrong or weak signal), check the
placement and alignment of the sensors. The use of a corner cube can also help to obtain a better
measurement result.