en_BA_RR30_IO-Link_V0.23.docx
13/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
4.3.2
SSC Configuration
All SSC1 setting can be applied also in the same way to SSC2.
4.3.3
Channel Logic
Allows to change the output logic from Normally Open (NO, Normal) to Normally closed (NC, Inverted).
Single Point Mode Window Mode
Single Point Mode Window Mode
Figure 8
«Normal» or NO setting
-
The
output is high
, when the object is
within the range defined by the setpoints.
-
The
output is low
when the object is not
present our outside of the range defined by
the setpoints
Figure 9
«Inverted» or NC setting
-
The
output is high
when the object is not
present our outside of the range defined by
the setpoints
-
the
output is low
, when the object is within
the range defined by the setpoints
Parameter name
Short Description
Rights
Unit / Allowed values
SSC1 Config.Logic
Selects the SSC logic. It can be
changed between "active if object
is present (normal)" or "inactive if
object is present (inverted)"
rw
-
Normal (NO) (Default)
-
Inverted (NC)
4.3.4
Switching Mode
Figure 10
Single point
A single switch point (SP1) is defined at which the
sensor switches.
Figure 11
Window Mode
The sensor switches within a range defined by two
different setpoints (SP1 and SP2)
Parameter name
Short Description
Rights
Unit / Allowed values
SSC1 Config.Mode
Selects the SSC switch mode
rw
-
Disabled
-
Single Point (Default)
-
Window