Parameter name
Short Description
Rights
Unit / Allowed values
Region of Interest.Start
Distance
Defines the Start of the Region
of interest within a signal
becomes visible at the output.
rw
Limits:
- 100 to 8500 mm
(Vers.: DAF0)
- 100 to 15500 mm
(Vers.: DAJ2)
- 100 to 82000 mm (Vers.:
DAO0)
Default = 100 mm
Region of Interest.End
Distance
Defines the End of the Region of
interest within a signal becomes
visible at the output.
rw
Limits:
- 100 to 8500 mm
(Vers.: DAF0)
- 100 to 15500 mm
(Vers.: DAJ2)
- 100 to 82000 mm
(Vers.: DAO0)
Default =
- 6500 mm (Vers.: DAF0)
- 12500 mm (Vers.: DAJ2)
- 62000 mm (Vers.: DAO0)
4.7
Expert settings
The following parameters are specific for this type of Radar sensors and are used to optimize the
performance of the sensor.
The table gives an overview of all expert settings parameters, while being followed by more detailed
explanations. After a profile is chosen the following procedure usually applies:
-
Adjust the sensitivity level
-
Choose the peak settings depending on respective environment
-
Adjust filters (Exponential Output / Disruption )
Parameter name
Short Description
Rights
Unit / Allowed values
Measurement Sensitivity
Scale
Select sensitivity level in 5
different scales from Very Low
to Very High.
rw
- Very High
- High
- Medium (Default)
- Low
- Very Low
Peak Setting Mode
Peak selection for the output
value calculation.
rw
- Highest Peak
- First Peak (default)
- Second Peak
- Last Peak
Operation Modes
Measurement Modes
Algorithm selection for the peak
calculations.
rw
- Fast
- Precise (default)
- Structured
- Precise
– all