en_BA_RR30_IO-Link_V0.23.docx
26/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
Peak
Value
Unit
Peak4.Amplitude
7.9
dB
Peak4.Distance
3710
mm
Peak3.Amplitude
14
dB
Peak3.Distance
3152
mm
Peak2.Amplitude
10.1
dB
Peak2.Distance
1812
mm
Peak1.Amplitude
6.5
dB
Peak1.Distance
1250
mm
Peak0.Amplitude
10
dB
Peak0.Distance
450
mm
Figure 24: Peak data (Distance and amplitude ) as an example from IO-Link Tool
d
B
Distance (mm)
200
2000
4000
0
3
1
2
4
30
20
10
0
Figure 25: Peak view (example)
There are four selection possible:
Highest Peak
o
Would select peak no. 3 from the example (Figure 25) which has the highest amplitude level
o
If only one peak available this one is selected
o
Use when the target is not always the first but has the strongest signal reflection
First Peak (default)
o
Would select peak no. 0 from the example
o
If only one peak available this one is selected
Second Peak
o
Would select peak no. 1 from the example
o
If only one peak is available none is selected
Last Peak
o
Would select peak no. 4 from the example
o
If only one peak available this one is selected
Содержание IO-Link RR30