en_BA_RR30_IO-Link_V0.23.docx
38/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
5.6.3
Process Value 1: Distance
Parameter name
Short Description
Rights
Unit / Allowed values
Distance Resettable Histogram
Reset
Command to reset the
histogram of process value 1
ro
Distance Resettable
Histogram.Mode
Standard means: Linear
partition of the range into
bins.
ro
Standard
Distance Resettable
Histogram.Unit
Indicates the unit
ro
Millimeter
Distance Resettable
Histogram.RangeStart
Defines, where the range
starts.
ro
0
Distance Resettable
Histogram.RangeEnd
Defines, where the range
ends.
ro
6000;
12000;
60000
Distance Resettable
Histogram.Nbr of Bins
Number of bins
ro
16
Distance Resettable
Histogram.Bin1 … 16
Number of counts of each bin ro
32 Bit for each bin