en_BA_RR30_IO-Link_V0.23.docx
22/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
4.6.2
Disruption Filter
This filter allows you to ignore interfering objects when passing through the measuring range either cyclic or
non-cyclic. This function depends on two parameters
Parameter name
Short Description
Rights
Unit / Allowed values
Process Value Disruption
Filter.Maximum perturbation
time
Duration (in units of time) until a
signal (as defined in the
parameter . Distance) becomes
visible at the output.
rw
Limits: 0 to 1000.000 ms
Default: 200 ms
Process Value Disruption
Filter.Distance
Distance deviations from the
current measured value which
are ignored, if shorter than the
period set by the parameter
“Process Value Disruption Filter
Maximum perturbation time
”.
rw
Limits 5 to 10.000 mm
Default: 300 mm
4.6.3
Region of Interest (ROI)
The region of interest is the space (in mm) in which the sensor performs. If a signal is detected in this region,
the data will be processed and the result displayed. All signals, even if detected by the sensor, being out of
this region are not processed and displayed further on. The ROI is not necessary the same as the analog
output region. But the analog one has to be inside the bounders of the ROI. See 4.8.2.
Содержание IO-Link RR30