en_BA_RR30_IO-Link_V0.23.docx
12/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
4.3
Switching Signal Channel (SSC)
The sensor features three different switching channels. Switching Signal Channels SSC1 and SSC2 are
reserved for distance measurements, whereas Switching Channel 4 has a counter function with an auto-
reset. All switching channels can be adjusted via IO-Link. All switching channels can be mapped to the MDC
as well.
For more information about how to set-up the Counter/SSC4 channel and its behavior, please see section 0.
4.3.1
Setpoint SP
Using this parameter the user can modify the switching point of the sensor by entering the distance value at
which the sensor should switch (teach-by-value function), change the value For Single point mode only SP1
is relevant, SP2 is not active. For the Window mode SP1 & SP2 are active. The switching modes are
explained in section 4.3.4
Figure 6
Single Point Mode
SP1: Switch point 1
SP2: is not active
Figure 7
Window Mode
SP1: Switch point 1
SP2: Switch point 2
Parameter name
Short Description
Rights
Unit / Allowed values
SSC1 Param.SP 1
Set the distance at which the related
SSC is set to active (or inactive if
inverted)
rw
Limits:
-
200 - 8000 mm;
-
300 - 15000 mm;
-
400 - 80000 mm;
Default: 1000 mm
SSC1 Param.SP 2
Set the distance at which the related
SSC is set to inactive (or active if
inverted). Only active if SSC is set to
window mode
rw
Limits:
-
200 - 8000 mm;
-
300 - 15000 mm;
-
400 - 80000 mm;
Default:
2000 mm; 5000 mm;
20000 mm