en_BA_RR30_IO-Link_V0.23.docx
30/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
Parameter name
Short Description
Rights
Unit / Allowed values
Analog
Output.Distance@AnalogMin
Set the distance value in
mm at the minimum value of
the Analog Output
rw
Limits:
- 200 to 8000 mm
(Vers.: DAF0)
- 300 to 15000 mm
(Vers.: DAJ2)
- 400 to 80000 mm
(Vers.: DAO0)
Default =
- 200 mm
- 300 mm
- 500 mm
Analog
Output.Distance@AnalogMax
Set the distance value in
mm at the maximum value
of the Analog Output
rw
Limits:
- 200 to 8000 mm
(Vers.: DAF0)
- 300 to 15000 mm
(Vers.: DAJ2)
- 400 to 80000 mm
(Vers.: DAO0)
Default =
- 6000 mm
- 12000 mm
- 60000 mm
4.9
Local User Interface
Different parameters are available to configure the local user interface which means the indication LEDs and
the local-teach-in (teach by wire)
4.9.1
Indication LEDs
Parameter name
Short Description
Rights
Unit / Allowed values
LED Settings.Green.Mode
Switches the LED off, no
change of other function
rw
On / Off
Default: On
LED Settings.Yellow.Mode
Switches the LED off, no
change of other function,
Inverted: Pin high, LED off
On: Pin high, LED on
rw
On / Off / Inverted
Default: On