en_BA_RR30_IO-Link_V0.23.docx
10/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
4
Parameter
RR30 Radar sensor are available in three different distance versions (6, 12 and 60 m). Therefore all allowed
or default values in list of this chapter will have three different values according to one of the versions.
wo= write only, ro= read only, rw= read and write
4.1
System Commands
A factory reset of the sensor activates the default parameters as set in the factory. All parameters changed
by the user will be lost.
Parameter name
Short Description
Rights
Unit / Allowed
values
Standard command
Restore Factory Settings
wo
4.2
Measurement Data Channel (MDC)
4.2.1
Measurement Value Distance
Parameter name
Short Description
Rights
Unit / Allowed
values
Measurement Value.
Distance
Process value for distance
ro
mm
4.2.2
Switch Counts
For each individual SSCx a switching counter is implemented. The number of counts of each channel can
also be mapped to the measurement data channel MDC by adjusting the MDC source. The Trigger of the
counter is on the positive slope of the elated SSC.
Parameter name
Short Description
Rights
Unit / Allowed
values
-
SSC1 Switch Counts
Reset
-
SSC2 Switch Counts
Reset
-
SSC4 Switch Counts
Reset
Command to set the counter value of
the SSC to zero
wo
-
Switch Counts.SSC1
Resettable
-
Switch Counts.SSC2
Resettable
-
Switch Counts.SSC4
Resettable
Total number of switch counts on
SSC1 (resettable by user command->
SSC1 Switch Counts Reset)
Available for SSC1,2 and 4.
ro
32 Bit value
Содержание IO-Link RR30
Страница 1: ...Instruction Manual Radar Sensor RR30 ...