en_BA_RR30_IO-Link_V0.23.docx
11/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
4.2.3
MDC Source
Selects which measuring value is mapped to the MDC channel and is then available via the process data-IN
path. When SSC1, SSC2 or SSC4 is selected the number of switches detected by the channel is shown.
Parameter name
Short Description
Rights
Unit / Allowed values
MDC Selection.Source
Select the process value that is
shown on the MDC channel
ro
- Distance (Default)
- Velocity
- Amplitude
- Switch Counter SSC1
- Switch Counter SSC2
- Switch Counter SSC4
4.2.4
MDC Unit Code
Parameter name
Short Description
Rights
Unit / Allowed values
MDC Descriptor.Unit
code
Indicates the unit of the selected
MDC source
ro
- Distance mm
- Velocity mm/s
- Amplitude dB
- SSC1, SSC2, SSC4 none
4.2.5
MDC Setpoint limit
This parameter allows to read out the limits of the measuring range of the sensor.
Parameter name
Short Description
Rights
Unit / Allowed values
MDC Descriptor.Lower
limit
Lower value of measuring range, if
value is below out of range is
shown
ro
A0: 200 mm; 300 mm; 500 mm;
depends on version of sensor
MDC Descriptor.Upper
limit
Upper value of measuring range, if
value is above out of range is
shown
ro
A0: 6000 mm; 12000 mm;
60000 mm; depends on version
of sensor
Содержание IO-Link RR30