en_BA_RR30_IO-Link_V0.23.docx
19/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
In section 3.1, the signal path is described more detailed, to illustrate how the counter module is
implemented. In section 4.3.8.2 the behavior is explained.
4.3.8.1
SSC4 Configuration
In general the SSC4 offers the same features as the SSC1 and SSC2 based on distance (See 4.3.2),
including also time filters.
Exceptions:
-
No hysteresis settings as there are only incremental counts.
-
Additional parameters to adjust like
SSC4 Source
and
SSC4 Auto-Reset.
Parameter name
Short Description
Rights
Unit / Allowed values
SSC4 Param.SP1
Set the number of counts at which
the SSC is set to active (or
inactive if inverted)
rw
0 … max = 2147483639
Counts, default 20
SSC4 Param.SP2
Set the number of counts at which
the SSC is set to inactive (or
active if inverted). only active if
SSC is set to window mode
rw
0 … max = 2147483639
Counts, default 0
Parameter name
Short Description
Rights
Unit / Allowed values
SSC4 Config.Logic
Selects the SSC logic. It can be
changed between active if object
is present (normal) or inactive if
object is present (inverted)
rw
- Normal (Default)
- Inverted
SSC4 Config.Mode
Selection of the switching mode
rw
- Disabled (Default)
- Single Point
- Window
SSC Source
Settings.SSC4 Selection
Select the switch counter that is
used as input of SSC4
rw
- SSC1 Switch Counter
(Default)
- SSC2 Switch Counter
SSC Source
Settings.SSC4 Auto
Reset
Auto Reset of switch counter if
value in SSC4 Param.SP1 is
reached
rw
- Enabled (Default)
- Disabled
Parameter name
Short Description
Rights
Unit / Allowed values
Release Delay.SSC4
Time
Sets / indicates the release delay
time in milliseconds for the
respective switching signal
channel (SSC).
rw
0 to 60000 ms
Default: 0 ms
Response Delay.SSC4
Time
Sets / indicates the response
delay time in milliseconds for the
respective switching signal
channel (SSC).
rw
0 to 60000 ms
Default: 0 ms
Minimal Pulse
Duration.SSC4 Time
Sets / indicates the minimal pulse
length in milliseconds for the
respective switching signal
channel (SSC).
rw
0 to 60000 ms
Default: 0 ms
Minimal Pulse
Duration.SSC4 Mode
0: Both Pulses: positive and
negative pulses are prolonged; 1:
Positive Pulse: only positive
pulses are prolonged; 2: Negative
rw
- Both Slopes (Default)
- Positive Slope
- Negative Slope