en_BA_RR30_IO-Link_V0.23.docx
14/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
4.3.5
Hysteresis Alignment Mode
In case of axial detection tasks like stop trigger or level detection, an accurate switching is required.
To adapt the switching behavior and the hysteresis to the movement direction of the object, the alignment of
the hysteresis can be changed.
Parameter name
Short Description
Rights
Unit / Allowed values
SSC1 Config.Hyst
Selects the hysteresis alignment
mode
rw
-
Left Aligned
-
Center Aligned
-
Right Aligned (Default)
4.3.5.1
Left Aligned
Left Aligned defines the hysteresis to be aligned towards the sensor / against the sensing direction.
When to apply?
-
For an accurate switching distance in case the object is moving away from the sensor
o
Example: Detection of the low level of a tank to avoid a dry-run
Figure 12
Left Aligned, Single Point Mode
Figure 13
Left Aligned, Window Mode
4.3.5.2
Right Aligned
Right Aligned defines the hysteresis to be aligned away from the sensor / in sensing direction.
When to apply?
-
For an accurate switching distance in case the object is moving towards the sensor.
o
Example: Stop trigger application, usual detection tasks.
Figure 14
Right Aligned, Single Point Mode
Figure 15
Right Aligned, Window Mode