en_BA_RR30_IO-Link_V0.23.docx
37/40
Baumer Electric AG
13.01.2021/
Frauenfeld, Switzerland
5.6.1
Device Temperature
Parameter name
Short Description
Rights
Unit / Allowed values
Device Temperature Lifetime
Histogram.Mode
Standard means: Linear
partition of the range into
bins.
ro
Standard
Device Temperature Lifetime
Histogram Unit
Indicates the unit
ro
°C, K, F
Device Temperature Lifetime
Histogram.RangeStart
Defines, where the range
starts.
ro
-40
Device Temperature Lifetime
Histogram.RangeEnd
Defines, where the range
ends.
ro
+120
Device Temperature Lifetime
Histogram.Nbr of Bins
Number of bins
ro
16
Device Temperature Lifetime
Histogram Bin1 … 16
Number of counts of each bin ro
32 Bit for each bin
5.6.2
Power Supply
Parameter name
Short Description
Rights
Unit / Allowed values
Power Supply Voltage Lifetime
Histogram.Mode
Standard means: Linear
partition of the range into
bins.
ro
Standard
Power Supply Voltage Lifetime
Histogram.Unit
Indicates the unit
ro
Volts
Power Supply Voltage Lifetime
Histogram.RangeStart
Defines, where the range
starts.
ro
0
Power Supply Voltage Lifetime
Histogram RangeEnd
Defines, where the range
ends.
ro
+48
Power Supply Voltage Lifetime
Histogram Nbr of Bins
Number of bins
ro
16
Power Supply Voltage Lifetime
Histogram Bin1 … 16
Number of counts of each bin ro
32 Bit for each bin