MergePoint Service Processor Manager SP53XX Installer/User Guide
NOTE: Automatic provisioning is an optional feature that is only available for target devices that have
IPMI BMCs.
Starting or stopping the BMC provisioning service (Admin users only)
You may start or stop the BMC provisioning service through the Provisioning window. If the Stop
button is clicked, the BMC provisioning service stops and the MergePoint SP manager will no
longer accept PXE boot requests from target devices on the LAN. However, previously provisioned
target devices that have IPMI BMCs can still be discovered.
To stop or start the BMC provisioning service:
1.
Click Targets - Provisioning.
2.
In the Provisioning window, click Stop or Start as appropriate.
Configuring PXE parameters for IPMI BMC provisioning (Admin users only)
You must configure provisioning parameters for a BMC that will be initialized and managed by the
MergePoint SP manager.
To set basic provisioning parameters in the MergePoint SP5300 appliance:
1.
Click Targets - Provisioning.
2.
Enter the username and gateway address in the fields provided.
3.
In both the Password and Confirm Password fields, enter the password.
4.
Check the VLAN Enable field if you need to use VLAN on BMC, and specify the following
VLAN parameters:
a.
In the VLAN ID field, type the VLAN ID.
b.
In the VLAN Priority field, type the VLAN priority.
5.
Click Apply.
NOTE: For the MergePoint SP5300 appliance, it is strongly recommended that the VLAN ID on the BMC and the
MergePoint SP5300 appliance are the same; otherwise, the BMC cannot communicate with the MergePoint
appliance in the VLAN mode.
To set basic provisioning parameters in the MergePoint SP5324/SP5340 appliance:
1.
Click Targets - Provisioning.
2.
In the Subnet drop-down menu, select a subnet.
3.
Enter the username and gateway address in the fields provided.
4.
In both the Password and Confirm Password field, enter the password.
5.
Select VLAN Enable to use VLAN on the BMC, and specify the following parameters:
a.
In the VLAN ID field, type the VLAN ID.
b.
In the VLAN Priority field, type the VLAN priority.
Содержание MERGEPOINT 53XX SP MANAGER
Страница 1: ...MERGEPOINT 53XX SP MANAGER Installer User Guide...
Страница 12: ...x MergePoint Service Processor Manager SP53XX Installer User Guide...
Страница 14: ...xii MergePoint Service Processor Manager SP53XX Installer User Guide...
Страница 22: ...8 MergePoint Service Processor Manager SP53XX Installer User Guide...
Страница 80: ...66 MergePoint Service Processor Manager SP53XX Installer User Guide...
Страница 96: ...82 MergePoint Service Processor Manager SP53XX Installer User Guide...
Страница 138: ...124 MergePoint Service Processor Manager SP53XX Installer User Guide...
Страница 160: ...146 MergePoint Service Processor Manager SP53XX Installer User Guide...
Страница 202: ...188 MergePoint Service Processor Manager SP53XX Installer User Guide...
Страница 203: ......
Страница 204: ...For Technical Support www avocent com support 590 839 501D...