3.4 AAQ Remote Network Settings Tool
The AAQ Remote Settings tool is utilized to customize the AAQ Network IP settings using login
level 4 or above.
Path
Main Window → File → Settings
AAQ Network Interface Options
Modems, beacon receivers, etc. will sometimes require the AAQ controller to be configured on
the device network, enabling communications between the two devices.
Figure 3.4 - Advanced Network Settings Tool
Window item
Description
DHCP
When the ACU is set to use DHCP, make sure that the server is also
a DNS server. Using a DHCP server without a DNS server will cause
the ACU to receive a valid IP address that is unknown to the user.
Customer Network 1 & 2
Customer IPs may be changed in accordance with customer device
requirements. Once a new address is entered, click “Apply” to
make the change.
Service Network
The service IP is permanent and available for recovery if
necessary. If a fault has occurred in setting the new IP Address, the
ACU defaults to the original 192.168.129.51 address.