6.3.6 Other Core Parameters
Long name
Level
Type
Value Range
Documentation
Modem Tx Restore On Open
4
Choice
"No", "Yes"
Restore the modem Tx enable when
modem is reopened after a failure.
Modem Tx Enable On Rx Lock
4
Choice
"No", "Yes"
Set modem Tx enabled if Rx Lock is
received during idle processing.
Position Hold Run Acquire on
Peak Fail
1
Choice
"No", "Yes"
If set to yes then the acquire command
will be run if peaking fails to find a lock
during position hold.
Controller Name
4
String
-
Name of the controller
Controller Serial Number
4
String
-
Serial number of the controller
Panel Connect Blocks Others
1
Choice
"No", "Yes"
This flag indicates whether other clients
are blocked when connected.
Rack Controller Field 0 - 9
1
String
-
Field Name for a single field to display in
the rack controller. Blank will skip the
field
Rack Controller Label 0 - 9
1
String
-
Label for a single field to display in the
rack controller.
Manual Control Allows
Modem Tx
4
Choice
“No”, “Yes”
When set to yes, doesn’t disable the tx
when manual control is run
Step Mode Sample Delay
4
Integer
0 to 1000
Delay in MS between testing and
retrying the step jog mode move
Step Mode Wobble
Correction
4
Choice
"No", "Yes"
Flag indicating that wobble correction
should be performed when the Pol is
changed
Circular Polarization Center
Position
4
Float
-90 to 90
Center position, in degrees, Of the
motorized circular pol
Feed Bit Override
4
Choice
"No", "Yes"
Flag indicating whether the feed bits are
overridden with a manual value
Feed Bit Override Type
4
Choice
, "C-LP", "X-LP", "Ku-LP", "Ka-LP", "C-
CP", "X-CP", "Ku-CP", "Ka-CP", "L", "S",
"Q", "Ka (EXTENDED)", "C-CP
(MOTORIZED)", "Ka-CP (MOTORIZED)",
"C-LP-2"
Value to override the feed bits with
The
Modem
configuration parameters are only valid if the AAQ is optionally configured to
communicate with the terminal’s modem. If this option has been exercised, then these parameters
specify the AAQ’s response under the specific conditions as described above in the Documentation
column. Also see the appendix documentation in accordance with the specific modem used.
The
Controller
parameters are set in the AvL factory and visible at all privilege levels for service and
maintenance purposes.
Wobble Correction
compensates for any mechanical offset which may occur during the movement
of the feed assembly and it’s operation depends upon the specific feed type used.