AvL Proprietary and Confidential
Content is Subject to Change without Notice
Page
113
of
195
Values for the
Signal Source
1 / 2 / 3
configuration parameters are selected on the left-hand side of the
Profile System window (see Figure 6.4). All valid Signal Sources are available for each step in all three
Acquisition attempts. As implied in the figure, up to three successive attempts will be made by the AAQ
to acquire the Target Satellite based on entries made in the Primary, Secondary and Tertiary sections.
This flexibility provides the Level 4 operator with the option of attempting the quickest, possibly least
reliable, method first knowing that the system will automatically progress to more robust acquisition
schemes.
Parameter choices for the standard systems are:
None – AAQ will skip that step in the Acquisition process.
ASC Beacon (if installed)
AVL Receiver (if installed)
ComTech (if installed)
DVB (if installed)
HughesHN (if installed)
iDirect (if installed)
Newtec
Novella Beacon (if installed)
Romantis (if installed)
RSL (default)
SkyEdgeII (if installed)
6.3.3 Manual Moves
Long name
Level
Type
Value Range
Documentation
Manual Control Azimuth Fast
Speed
4
Float
0.1 - 100.0
Speed in degrees per second for manual control of the
azimuth motor in fast mode.
Manual Control Azimuth Slow
Speed
4
Float
0.1 - 100.0
Speed in degrees per second for manual control of the
azimuth motor in slow mode.
Manual Control Elevation Fast
Speed
4
Float
0.1 - 100.0
Speed in degrees per second for manual control of the
elevation motor in fast mode.
Manual Control Elevation Slow
Speed
4
Float
0.1 - 100.0
Speed in degrees per second for manual control of the
elevation motor in slow mode.
Manual Control Polarization Fast
Speed
4
Float
0.1 - 100.0
Speed in degrees per second for manual control of the
pol motor in fast mode.
Manual Control Polarization Slow
Speed
4
Float
0.1 - 100.0
Speed in degrees per second for manual control of the
pol motor in slow mode.
Manual Control Allow Modem Tx.
4
Choice
"No", "Yes"
When set to “Yes”, does not disable Tx in Manual mode.
Step Mode Sample Delay
4
Integer
0 – 1000
Delay in ms between testing and retrying the step jog
mode move
The speed at which the antenna moves when manually jogged is set by the
Manual _ Speed
parameters. Each of the three axes is set independently. Two speed settings are available; “Fast”
and “Slow.”