4-32
Maximus Reference Manual
MANU-MAXIMUS-02
Revision-02
Test Mode
Chapter 4: Color Terminals
Keypad Test
This tests each numeric and function key on the terminal. If you press an incorrect key the
system will beep and the red LED (X) flashes. When you successfully complete the test the
system exits to the next test. You can press the
clear
key to exit before completing the test.
Press the
enter
key when the display reads “
Test Mode Keypad Test
” to start the test then:
•
Press the numbers
1
–
9
then
0
in order.
•
Press the function buttons, starting at the top on the left in order down to the
bottom on the left (“F1” to “F4”), then the top on the right down to the
bottom on the right (“F5 to “F8”). These display as A through H.
DIDO Test 1
Press the
enter
key when the display reads “
Test Mode DIDO Test 1
” to start the test. The
test runs then displays the result. Press the
clear
key to exit the test before it finishes.
•
DIDO Test 2
– Press the
enter
key when the display reads “
Test Mode DIDO
Test 2
” to start the test. Press the clear key to exit the test before it finishes.
GSM Signal Strength
This option only appears with a GSM / GPRS module installed and used primarily when
installing a 5-meter antenna (see
"GSM Long Cable Antenna" on page 2-14
). Press the
enter
key when the display reads “
Test Mode GSM Signal Strength
” to start the test. The test
displays the signal strength of the cellular data network received by the GSM antenna. Move
the terminal, antenna, or both to change the received signal strength. You need a signal
strength of at least 15 for a GSM/GPRS module. Press the
clear
key to exit when finished.
RTC Test
Press the
enter
key when the display reads “
Test Mode RTC Test
” to start the test. This tests
the real-time clock (HW and SW) and beeps every second. Press the
clear
key to exit the test
when finished.
Battery/Charger Test
Press the
enter
key when the display reads “
Test Mode Battery/Charger Test
” to enter the
test and display the “
Battery/Charger Test Press Enter to Test
” prompt. Press the
enter
key
to test the components of the optional backup battery and proceed to the next test. The status
of each component displays on the screen each time you press the enter key. The tests are for
the UPS (Present or not), Battery (OK or Not OK), and AC (Present or not). Press the
clear
key
to exit when finished
USB Test
Press the
enter
key when the display reads “
Test Mode USB Test
” to enter the test and
display the “
USB Storage Test Attach drv, tap Enter
” prompt. Open the terminal and install
a USB flash drive into the USB port then press the
enter
key. The results appear on the screen
when the test completes (e.g.,
Passed
). Remove the USB flash drive and press the
clear
key to
exit.
Signal strength measures from 0 to 32 with 15 or higher being best.
NOTE:
Содержание Maximus MCJ2000 Series
Страница 8: ...P 2 Maximus Reference Manual MANU MAXIMUS 02 Revision 02 This page intentionally left blank...
Страница 118: ...4 2 Maximus Reference Manual MANU MAXIMUS 02 Revision 02 Chapter 4 Color Terminals This page intentionally left blank...
Страница 154: ...5 2 Maximus Reference Manual MANU MAXIMUS 02 Revision 02 Chapter 5 Maintenance This page intentionally left blank...
Страница 166: ...A 2 Maximus Reference Manual MANU MAXIMUS 02 Revision 02 Appendix A Biometrics This page intentionally left blank...
Страница 192: ...C 2 Maximus Reference Manual MANU MAXIMUS 02 Revision 02 Appendix C Using the USB This page intentionally left blank...
Страница 212: ...Index IX 14 Maximus Reference Manual MANU MAXIMUS 02 Revision 02...
Страница 213: ...This page intentionally left blank...