13. Connection of boilers DCxxS, CxxS, ACxxS, KCxxS,
DCxxRS with built-in burner in upper doors with accumu-
lation tank for regulation of the burner based on sensors TS
and TV and control of boiler pump based on TK sensor
INFO -
The TK sensor on the accumulation tank, sensors TV and TS on the accumulation
tank, all connected directly to the burner. The AD03 module is inserted under the instru-
ment hood of the boiler and is connected to the terminal board of the boiler (AD03 module
- LC clamp - pump, LA clamp - fan), where it controls the extraction fan of the boiler and
the pump in the boiler circuit..
Required accessories
(not part of the burner): module AD03, three KTF 20 sensors
System configuration of parameters:
S6 = 4, S14 = 13, S15 = 2
(reserve R – parameter S6 controls the boiler fan, reserve R2 – parameter S14 controls the boiler
pump)
WARNING
– for boilers with a burner built in the upper doors, it is not possible to use the
function of controlling solar heating directly from the pellet burner
A45