Operation and Maintenance Manual - GB
G
B
www.atmos.cz
GB-49
• Calibr.
– This function makes it possible to calibrate inputs for temperature sensors with the use of
special calibration aids –
function for the manufacturer only.
• Language
– This is the selection function of the language in which the burner communicates with the user.
The basic version of the program contains these language versions:
CZ - Czech, DE - German, EN - English, FR - French, IT - Italian, SP - Spanish, SE - Swedish,
PO - Portuguese, RO - Romanian, PL - Polish, HU - Hungarian and IT - Italian
INFORMATION menu
• Photocell
– Displays the
current value
that the photocell sees.
• Temperature TS – displays the current TS temperature
- (exhaust temperature (S15 = 1) or
lower temperature (S15 = 2))
• Temperature TV – displays the current TV temperature
- (water temperature (S15 = 1) or upper
temperature (S15 = 2))
• Temperature TK – displays the current TK temperature
- (boiler temperature ( S15 = 1, S15 = 2,
S15 = 4, S6 = 12, S6 = 13, S14 = 12, S14 = 13), central tank temperature ( S15 = 3, S6 = 14, S14
= 14 ), central tank temperature as a second deactivation sensor for burner TS2 (S26 = 0))
• Temperature TSV – displays the current TSV temperature
- (exhaust temperature (S15 = 1, S15
= 2, S15 = 4, S34 = 1, S34 = 2), solar collector temperature (S15 = 3, S6 = 14, S14 = 14))
Short explanation:
This always depends on whether the burner regulation function based on two temperatures on the
accumulation tank is on or off, and whether the automatic start function after wood burns out is ac-
tivated.
The default settings are S15=1 and S34=0,
which means that the
function for controlling
the burner by two sensors is deactivated
and the AUTOSTART function for DCxxSP(EP) burns
is also off. The burner is only controlled by thermoregulators on the boiler panel. The customer may
connect the exhaust temperature sensors TS and TSV and the water temperature sensors TV and TK
to the burner so that they
only serve as information.
If we
set S15 = 2, the function for regulation by two temperatures on the tank is activated and so
we connect the water tempearture sensor in the lower part of the tank TS and the water tempe-
rature sensor in the upper part of the tank TV to the
clamps of the burner connector.
If we set S15=3, the function for regulation by two temperatures on the tank is also activated,
simultaneously with the solar functions. It is thus also necessary to connect the TK sensor loca-
ted in the middle of the accumulation tank between the TV and TS sensors and the TSV solar
collector sensor.
If we are going to use the AUTOSTART function for boilers DCxxSP (S34 = 1 or S34 = 2), we
must also connect the TK sensor as a boiler sensor and the TSV sensor as the exhaust tempera-
ture sensor. It is not used with the A45 burner.