CAUTION
- the direct controlling function of solar heating from pellet burner cannot be used
for DCxxSP(EP) boilers and boilers with burner built into the upper doors. This function also
cannot be used when the pump is simultaneously controlled in the boiler circuit from the bur-
ner regulation (TK sensor cannot be simultaneously in boiler and accumulation tank)
o) S6 = 15
….. Reserve function for the compressor control during the function for automatic
burner cleaning using compressed air. Power element designed for switching and powering the
compressor (e.g. contactor) must be connected between reserve output R and the compressor. This
function is connected with S6(14), S41, S42, S43, S44, S45, S46, S47 parameter, which must be
checked and configured.
p) S6 = 16
….. Reserve function for controlling el.fan during the function for automatic burner
cleaning using compressed air. This function is connected with S6(14), S41, S42, S43, S44, S45,
S46, S47 parameter, which must be checked and configured.
Special function for turning on reserve output R according to the temperature of a concrete
sensor:
a) e.g. function:
TS>……. means that if the TS sensor temperature is higher then the set value in
S48 parameter – Temperature A, reserve output R will be activated
b) e.g. function:
TS<……. means that if the TS sensor temperature is higher then the set value in
S48 parameter – Temperature A, reserve output R will be deactivated
c) e.g. function:
TS,TV>……. means that if the TS and TV sensor temperature is higher at the
same time then the set value in S48 parameter – Temperature A and S50 – Temperature B, reserve
output R will be activated (Temperature A = first position (TS), Temperature B = second position
(Tv)).
d) e.g. function
TS,TK<……. means that if the TS and TK sensor temperature is higher at the
same time then the set value in S48 parameter – Temperature A and S50 – Temperature B, reserve
output R will be deactivated (Temperature A = first position (TS), Temperature B = second posi-
tion (Tk)).
Individual functions:
(17) TS>
(18) TS<
(19) TV>
(20) TV<
(21) TK>
(22) TK<
(23) TSV>
(24) TSV<
(25) TS,TV>
(26) TS,TV<
(27) TS,TK>
(28) TS,TK<
(29) TS,TSV>
(30) TS,TSV<
(31) TV,TK>
(32) TV,TK<
(33) TV,TSV>
(34) TV,TSV<
(35) TK,TSV>
(36) TK,TSV<