798
32072H–AVR32–10/2012
AT32UC3A3
29.7.1
Control Register
Name:
CR
Access Type:
Write-only
Offset:
0x00
Reset Value:
0x00000000
• START: Start Conversion
Writing a one to this bit will begin an analog-to-digital conversion.
Writing a zero to this bit has no effect.
This bit always reads zero.
• SWRST: Software Reset
Writing a one to this bit will reset the ADC.
Writing a zero to this bit has no effect.
This bit always reads zero.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
–
–
–
–
–
–
START
SWRST