76
32072H–AVR32–10/2012
AT32UC3A3
7.6.18
BOD33 Control Register
Name:
BOD33
Access Type:
Read/Write
Offset:
0xD4
Reset Value:
0x0000010X
• KEY: Register Write protection
This field must be written twice, first with key value 0x55, then 0xAA, for a write operation to have an effect.
• FCD: BOD33 Fuse calibration done
Set to 1 when LEVEL field has been updated by the Flash fuses after power-on reset or Flash fuses update
If one, the LEVEL value will not be updated again by Flash fuses
Can be cleared to allow subsequent overwriting of the value by Flash fuses
• CTRL: BOD33 Control
0: BOD33 is off
1: BOD33 is enabled and can reset the chip
2: BOD33 is enabled and but cannot reset the chip. Only interrupt will be sent to interrupt controller, if enabled in the IMR
register.
3: BOD33 is off
• LEVEL: BOD33 Level
This field sets the triggering threshold of the BOD33. See Electrical Characteristics for actual voltage levels.
Note that any change to the LEVEL field of the BOD33 register should be done with the BOD33 deactivated to avoid spurious
reset or interrupt.
31
30
29
28
27
26
25
24
KEY
23
22
21
20
19
18
17
16
-
-
-
-
-
-
-
FCD
15
14
13
12
11
10
9
8
-
-
-
-
-
-
CTRL
7
6
5
4
3
2
1
0
-
-
LEVEL
Содержание AT32UC3A3128
Страница 61: ...61 32072H AVR32 10 2012 AT32UC3A3 PLLEN PLL Enable 0 PLL is disabled 1 PLL is enabled...
Страница 260: ...260 32072H AVR32 10 2012 AT32UC3A3 5 2560 3071 6 3072 3583 7 3584 4095 Bit Index n Sector Boundaries...
Страница 592: ...592 32072H AVR32 10 2012 AT32UC3A3 Manchester Configuration Register on page 614...
Страница 989: ...989 32072H AVR32 10 2012 AT32UC3A3 37 2 Package Drawings Figure 37 1 TFBGA 144 package drawing...
Страница 991: ...991 32072H AVR32 10 2012 AT32UC3A3 Figure 37 3 VFBGA 100 package drawing...