369
32072H–AVR32–10/2012
AT32UC3A3
19.12.15 Combined Interrupt Status Registers
Name: StatusInt
Access Type: Read-only
Offset:
0x360
Reset Value:
0x00000000
The contents of each of the five Status Registers (StatusTfr, StatusBlock, StatusSrcTran, StatusDstTran, StatusErr) is
OR’ed to produce a single bit per interrupt type in the Combined Status Register (StatusInt).
• ERR
OR of the contents of StatusErr Register.
• DSTT
OR of the contents of StatusDstTran Register.
• SRCT
OR of the contents of StatusSrcTran Register.
• BLOCK
OR of the contents of StatusBlock Register.
• TFR
OR of the contents of StatusTfr Register.
31
30
29
28
27
26
25
24
-
-
-
-
-
-
-
-
23
22
21
20
19
18
17
16
-
-
-
-
-
-
-
-
15
14
13
12
11
10
9
8
-
-
-
-
-
-
-
-
7
6
5
4
3
2
1
0
-
-
-
ERR
DSTT
SRCT
BLOCK
TFR
Содержание AT32UC3A3128
Страница 61: ...61 32072H AVR32 10 2012 AT32UC3A3 PLLEN PLL Enable 0 PLL is disabled 1 PLL is enabled...
Страница 260: ...260 32072H AVR32 10 2012 AT32UC3A3 5 2560 3071 6 3072 3583 7 3584 4095 Bit Index n Sector Boundaries...
Страница 592: ...592 32072H AVR32 10 2012 AT32UC3A3 Manchester Configuration Register on page 614...
Страница 989: ...989 32072H AVR32 10 2012 AT32UC3A3 37 2 Package Drawings Figure 37 1 TFBGA 144 package drawing...
Страница 991: ...991 32072H AVR32 10 2012 AT32UC3A3 Figure 37 3 VFBGA 100 package drawing...