SRV-63 series AC servo drives Control mode applications
-44-
Signal name
Sign
Function number Available mode
Zero speed clamp
ZRS
0x0D
S
T
This function serves as the control signal of zero speed clamp and please refer to P0.58 for
detailed information.
Signal name
Sign
Function number Available mode
Speed command sign
S-SIGN
0x0E
S
This function is the sign selection of speed command input in the speed control mode.
If P0.41 is 1, the input function is valid, and when the setting is 0, the function is invalid.
Signal name
Sign
Function number Available mode
Torque command sign
T-SIGN
0x0F
T
This function is the sign selection of torque command input in the torque control mode.
If P0.61 is 1, the input function is valid, and when the setting is 0, the function is invalid.
Signal name
Sign
Function number Available mode
Internal position command 1
POS1
0x10
P
Internal position command 2
POS2
0x11
P
Internal position command 3
POS3
0x12
P
Internal position command 4
POS4
0x13
P
Internal position command 5
POS5
0x20
P
Internal position command 6
POS6
0x21
P
Internal position command 7
POS7
0x22
P
These functions are the selections of 0~127 in the PTP (point-to-point) control mode. It has the
same function with P5.20 and is valid when P0.20 is 2.
The combination of 7 digital inputs is used to select the different PTP position of
PtP0.00~PtP2.55 and the corresponding target speed, ACC/DEC time and the delay time of
P5.21~P5.68.
Control mode POS7 POS6 POS5 POS4 POS3 POS2 POS1 Parameters and setting value
Position mode
0
0
0
0
0
0
0
PtP0.01[0
th
position]
0
0
0
0
0
0
1
PtP0.03[1
st
position]
0
0
0
0
0
1
0
PtP0.05[2
nd
position]
0
0
0
0
0
1
1
PtP0.07[3
rd
position]
0
0
0
0
1
0
0
PtP0.09[4
th
position]
0
0
0
0
1
0
1
PtP0.11[5
th
position]
0
0
0
0
1
1
0
PtP0.13[6
th
position]
0
0
0
0
1
1
1
PtP0.15[7
th
position]
0
0
0
1
0
0
0
PtP0.17[8
th
position]
0
0
0
1
0
0
1
PtP0.19[9
th
position]
0
0
0
1
0
1
0
PtP0.21[10
th
position]
0
0
0
1
0
1
1
PtP0.23[11
th
position]
0
0
0
1
1
0
0
PtP0.25[12
th
position]
x
x
x
x
x
x
x
xxx