SRV-63 series AC servo drives Running and operation
-74-
Sign
Name
Jogging test
Restore the factory parameter
Program commissioning
Analog input 1 zero drift clear
Analog input 2 zero drift clear
Analog input 3 zero drift clear
Inertia identification
Absolute value encoder clear
Note: The auxiliary functions can be operated only when servo is disabled, otherwise users cannot
enter the auxiliary function menu.
5.2.5.2 Operation flowchart of trial jogging
Press
MODE
key to switch to the auxiliary function mode. Press
UP/DOWN
key to the
menu, and press
SET
key to the jogging interface. The interface will display the current speed of the
motor. Press
UP
key, the motor will rotate to the setting speed anticlockwise and stops when
releasing the key. Press
DOWN
key, the motor will rotate to the setting speed clockwise and stops
when releasing the key.
MODE
SET
UP press
down
UP release
DOWN press
down
DOWN
release
5.2.5.3 Operation flowchart of restoring the factory parameter
Press
MODE
key to switch to the auxiliary function mode.
Press
UP/DOWN
key to the
menu, and press
SET
key to the interface. The interface will display
. Press
SET
key to
restore to the factory values, it will display
, after finishing, it will display
. The
Operation flowchart of analog speed reference zero drift clear, analog torque reference zero drift clear
and analog torque reference zero drift clear are the same.
MODE
SET
SET
MODE