SRV-63 series AC servo drives Detailed parameter description
-125-
This parameter can be used to adjust the AO1 and AO2 to regulate the actual value of analog
output voltage.
Actual value of analog output voltage = Original value of analog output v Offset value of
analog output voltage
P3.34
Data size
32bit
Data format
DEC
Modbus address
1668,1669
CANopen address
0x2322,0x00
P3.35
Data size
32bit
Data format
DEC
Modbus address
1670,1671
CANopen address
0x2323,0x00
P3.36
1
Analog output monitor
setting
Setting range
Default
Unit
Available mode
0~2
0
-
P
S
T
F
This parameter is used to set the output mode and voltage range of the analog output.
Setting value
Output mode
[0]
Voltage output with sign(-10V~10V)
1
Absolute voltage output (0V~10V)
2
Voltage output with zero offset (0V~10V, 5V center)
P3.36
1
Data size
16bit
Data format
DEC
Modbus address
1672,1673
CANopen address
0x2324,0x00
6.4.3 Digital input / output settings
P3.40
1
Travel limit switch shield
Setting range
Default
Unit
Available mode
0~2
1
-
P
S
T
F
This parameter is used to set whether the digital input configured as forward drive disabling
(0x001 or 0x101) and reverse drive disabling (0x002 or 0x102) is valid or not. If the function of the
travel limit switch needs to be shielded , this parameter can do the trick.
Setting value
Function
0
Travel limit switch is normal
[1]
Travel limit switch is disabled
2
Ultralimit fault
Note:
When the travel limit switch is normal and the digital input configured as forward drive
disabling is active, the motor will stop immediately and cannot continue to run forward, but it is
able to receive the reverse running command.
P3.40
1
Data size
16bit
Data format
DEC
Modbus address
1680,1681
CANopen address
0x2328,0x00
P3.41
1
Emergency stop switch
shield
Setting range
Default
Unit
Available mode
0~1
1
-
P
S
T
F
This parameter is used to set whether digital input configured as EMG (0x016 or 0x116) is valid or
not. If the function of the emergency stop switch needs to be shielded, this parameter can do the
trick.