SRV-63 series AC servo drives Appendix
-269-
Function
code
Name
Unit
Range
Available
Mode
R1.09
Voltage of analog output 2
V
-10.000~10.000
PSTF
R1.10
Voltage of analog output 3
V
-10.000~10.000
PSTF
R1.11
Cumulative value of pulse input
reference unit
-(2
31
-1)~(2
31
-1)
PSTF
R1.12
Pulse position command
reference unit
-(2
31
-1)~(2
31
-1)
PSTF
R1.13
Pulse speed command
r/min
-10000.0~10000.0
PSTF
R1.14
Analog compensation speed
r/min
-10000.0~10000.0
PSTF
R1.15
Analog compensation torque
%
-1000.0~1000.0
PSTF
R1.16
DI capture encoder value
pulse
-(2
31
-1)~(2
31
-1)
PSTF
R2 Factory monitoring parameter
-
-
-
-
-
R3 Fault record parameter
R3.00
Fault code record
-
-
PSTF
R3.01
Power on time when fault occurs
s
0~(2
31
-1)
PSTF
R3.02
Operation time when fault occurs
s
0~(2
31
-1)
PSTF
R3.03
Motor speed when fault occurs
r/min
-20000~20000
PSTF
R3.04
Speed command when fault occurs
r/min
-20000~20000
PSTF
R3.05
Feedback pulse accumulation when
fault occurs
reference unit
-(2
63
-1)~(2
63
-1)
PF
R3.06
Command pulse accumulation when
fault occurs
reference unit
-(2
63
-1)~(2
63
-1)
PF
R3.07
Stranded pulse when fault occurs
reference unit
-(2
31
-1)~(2
31
-1)
PF
R3.08
Current torque when fault occurs
%
-500.0~500.0
PSTF
R3.09
Main circuit DC voltage when fault
occurs
V
0.0~1000.0
PSTF
R3.10
Output voltage when fault occurs
Vrms
0.0~1000.0
PSTF
R3.11
Output current when fault occurs
Arms
0.00~1000.00
PSTF
R3.20
Latest fault record
-
-
PSTF
R3.21
Latest 2 fault record
-
-
PSTF
R3.22
Latest 3 fault record
-
-
PSTF
R3.23
Latest 4 fault record
-
-
PSTF
R3.24
Latest 5 fault record
-
-
PSTF
R3.25
Latest 6 fault record
-
-
PSTF
R3.26
Latest 7 fault record
-
-
PSTF
R3.27
Latest 8 fault record
-
-
PSTF
R3.28
Latest 9 fault record
-
-
PSTF
R3.29
Latest 10 fault record
-
-
PSTF