SRV-63 series AC servo drives Appendix
-273-
Fault
code
Name
Feature
History record Can be cleared Disable
Er24-1
PROFIBUS-DP fault
–PWK Parameters exceeds the
range
●
Er24-2 PROFIBUS-DP fault
–PWK Parameters are read-only
●
Er24-3
PROFIBUS-DP fault
–PZD Configuration parameter
does not exist
●
Er24-4
PROFIBUS-DP fault
–PZD Configuration parameter
properties do not match
●
Er24-8 EtherCAT fault
–initialization fault
●
●
Er24-9 EtherCAT fault
–EEPROM fault
●
●
Er24-a EtherCAT fault
–DC Sync0 signal is abnormal
●
●
●
Er24-b EtherCAT fault
–Disconnection fault
●
●
●
Er24-c EtherCAT fault
–PDO data loss fault
●
●
●
Er25-4 Application fault
–Encoder offset angle test overtime
●
●
●
Er25-5 Application fault
–Encoder offset angle test failure
●
●
●
Er25-6 Application fault
–Offside of homing
●
●
●
Er25-7 Application fault
–Inertia identification failure
●
●
●
Er26-0 CANopen fault
–CANopen disconnection
●
Er26-1 CANopen fault
–SDO index does not exist
●
Er26-2 CANopen fault
–SDO sub index does not exist
●
Er26-3 CANopen fault
–SDO data length error
●
Er26-4 CANopen fault
–SDO W data exceeds the scope
●
Er26-5 CANopen fault
–Read-only cannot be modified
●
Er26-6 CANopen fault
–PDO mapping length error
●
Er26-7 CANopen fault
–PDO mapping data does not exist
●
Er26-8
CANopen fault
–PDO is not allowed to be modified
during operating
●
Er26-9 CANopen fault
–PDO mapping is not allowed
●
Er26-a CANopen fault
–Sync signal is too fast
●
Er26-b CANopen fault
–Receive fault
●
Er26-c CANopen fault
–Send failure
●
Er26-d CANopen fault
–Sync signal repeat
●
Er26-e CANopen fault
–The bus load rate is too high
●
Er26-f CANopen fault
–Parameter modification state error
●