SRV-63 series AC servo drives Detailed parameter description
-201-
R1.00
Data size
16bit
Data format
HEX
Modbus address
4200,4201
CANopen address
0x3100,0x00
R1.01
Data size
16bit
Data format
HEX
Modbus address
4202,4203
CANopen address
0x3101,0x00
R1.02
Original voltage of analog
input 1
Display range
Precision
Unit
-10.000~10.000
0.001
V
Display the original voltage value of analog input channel 1
R1.02
Data size
32bit
Data format
DEC
Modbus address
4204,4205
CANopen address
0x3102,0x00
R1.03
Original voltage of analog
input 2
Display range
Precision
Unit
-10.000~10.000
0.001
V
Display the original voltage value of analog input channel 2
R1.03
Data size
32bit
Data format
DEC
Modbus address
4206,4207
CANopen address
0x3103,0x00
R1.04
Original voltage of analog
input 3
Display range
Precision
Unit
-10.000~10.000
0.001
V
Display the original voltage value of analog input channel 3
R1.04
Data size
32bit
Data format
DEC
Modbus address
4208,4209
CANopen address
0x3104,0x00
R1.05
Voltage of analog input 1
Display range
Precision
Unit
-10.000~10.000
0.001
V
Display the calibrated voltage value of analog input channel 1.
R1.05
Data size
32bit
Data format
DEC
Modbus address
4210,4211
CANopen address
0x3105,0x00
R1.06
Voltage of analog input 2
Display range
Precision
Unit
-10.000~10.000
0.001
V
Display the calibrated voltage value of analog input channel 2
R1.06
Data size
32bit
Data format
DEC
Modbus address
4212,4213
CANopen address
0x3106,0x00
R1.07
Voltage of analog input 3
Display range
Precision
Unit
-10.000~10.000
0.001
V
Display the calibrated voltage value of analog input channel 3
R1.07
Data size
32bit
Data format
DEC
Modbus address
4214,4215
CANopen address
0x3107,0x00