SRV-63 series AC servo drives Control mode applications
-43-
Signal name
Sign
Function number Available mode
Gain switching
PLC
0x06
P
S
T
F
This function is the control signal of 1
st
and 2
nd
gain switching.
Signal name
Sign
Function number Available mode
Retention pulse clearing
RPC
0x07
P
F
This function is the control signal of retention pulse clearing and the detailed operation is relative
to the setting of P3.45.
P3.45=0 means electrical level clear. When the digital input is valid, retention pulse will be 0;
P3.45=1 means rising edge clear. When the digital input triggers retention pulse clearing from the
edge of 0
→1, only clear once.
Signal name
Sign
Function number Available mode
Command pulse disabled
PLL
0x08
P
F
This function is the control signal of stopping receiving the command pulse and the detailed
operation is relative to the setting of P3.44.
P3.44 is 0, the function is valid and when P3.44 is 1, the function is invalid.
Signal name
Sign
Function number Available mode
Torque limit switching
TLC
0x09
P
S
F
This function is the control signal of 1
st
and 2
nd
torque limit switching.
Please refer to the instruction of P0.09.
Signal name
Sign
Function number Available mode
Internal speed command 1
SPD1
0x0A
S
T
Internal speed command 2
SPD2
0x0B
S
T
Internal speed command 3
SPD3
0x0C
S
There are 1~8 signal selections for the internal speed command and 1~4 for the internal speed limit.
Control mode P0.40 setting value SPD3 SPD2 SPD1
Parameters and setting value
Speed mode
0
0
0
0
P0.46 internal speed 1
0
0
1
P0.47 internal speed 2
0
1
0
P0.48 internal speed 3
0
1
1
P0.49 internal speed 4
1
0
0
P0.50 internal speed 5
1
0
1
P0.51 internal speed 6
1
1
0
P0.52 internal speed 7
1
1
1
P0.53 internal speed 8
Torque mode
0
0
0
0
P0.46 speed limit 1
0
0
1
P0.47 speed limit 2
0
1
0
P0.48 speed limit 3
0
1
1
P0.49 speed limit 4