SRV-63 series AC servo drives Control mode applications
-48-
The function is the state signal when the drive displays the fault alarm.
When it is valid, the drive has fault.
Signal name
Sign
Function number Available mode
External brake release signal
BRK
0x05
P
S
T
F
The function is the control release signal of output motor brake.
When it is valid, the control brake is released and then it receives the motor control command;
when invalid, the control brake will be disconnected.
Signal name
Sign
Function number Available mode
Position command or not
PCMD
0x06
P
F
The function is the state signal of whether there is position command or not.
When it is valid, the motor is controlled by the non-zero position command.
Signal name
Sign
Function number Available mode
Positioning finished
PLR
0x07
P
F
The function is the state signal of positioning finished.
When it is valid, the positioning is finished.
Signal name
Sign
Function number Available mode
Control mode switching
MCHS
0x08
P
S
T
This function is the state signal during control mode switching in output compound control mode.
When it is valid, control mode 1 is switched to mode 2; if the function output is invalid, the control
mode 2 is switched back to mode 1.
Signal name
Sign
Function number Available mode
Speed matching
COIN
0x09
P
S
T
F
The function is the state signal of speed matching.
When it is valid, the deviation between current speed feedback and speed command is in the
range of P3.53.
Signal name
Sign
Function number Available mode
Speed reaching
SR
0x0A
P
S
T
F
The function is the state signal of output speed reaching.
When it is valid, the current speed feedback is in the setting value of P3.54.
Signal name
Sign
Function number Available mode
Speed limiting
SL
0x0B
T
The function is the state signal of speed limiting.
When it is valid, in the torque mode, if the current torque does not reach the torque command, the
speed feedback is in the speed limiting.
Signal name
Sign
Function number Available mode
Speed command or not
SCMD
0x0C
P
S
T
F