SRV-63 series AC servo drives Detailed parameter description
-152-
Signal
Function
[-1]
Invalid
0-127
Control 0-127 step, equivalent to digital input: TRIG + POSn
function.
128-2047
Invalid
2048
Forced to stop
Example: Writing PTP signal 3 means to trigger the PTP program 3.
P5.20*
Data size
16bit
Data format
DEC
Modbus address
2040,2041
CANopen address
0x2514,0x00
P5.21
00 target speed
Setting range
Default
Unit
Available mode
0~6000
20
r/min
P
P5.22
01 target speed
Setting range
Default
Unit
Available mode
0~6000
50
r/min
P
P5.23
02 target speed
Setting range
Default
Unit
Available mode
0~6000
100
r/min
P
P5.24
03 target speed
Setting range
Default
Unit
Available mode
0~6000
200
r/min
P
P5.25
04 target speed
Setting range
Default
Unit
Available mode
0~6000
300
r/min
P
P5.26
05 target speed
Setting range
Default
Unit
Available mode
0~6000
500
r/min
P
P5.27
06 target speed
Setting range
Default
Unit
Available mode
0~6000
600
r/min
P
P5.28
07 target speed
Setting range
Default
Unit
Available mode
0~6000
800
r/min
P
P5.29
08 target speed
Setting range
Default
Unit
Available mode
0~6000
1000
r/min
P
P5.30
09 target speed
Setting range
Default
Unit
Available mode
0~6000
1300
r/min
P
P5.31
10 target speed
Setting range
Default
Unit
Available mode
0~6000
1500
r/min
P
P5.32
11 target speed
Setting range
Default
Unit
Available mode
0~6000
1800
r/min
P
P5.33
12 target speed
Setting range
Default
Unit
Available mode
0~6000
2000
r/min
P
P5.34
13 target speed
Setting range
Default
Unit
Available mode
0~6000
2300
r/min
P
P5.35
14 target speed
Setting range
Default
Unit
Available mode
0~6000
2500
r/min
P