5
ART
Tracking Controllers
5.4 Cascaded systems
Cascading means that two or more stand-alone tracking systems are combined to one
large system in order to have only one consolidated data output. It is possible to cas-
cade
TRACKPACK/E
systems with or without
ARTTRACK5
and
ARTTRACK5/C
and to
build cascades out of
ARTTRACK
(discontinued) with
TRACKPACK
systems (discon-
tinued). Therefore, the system is subdivided into one master and up to eight slaves.
However, the total number of cameras in the cascaded system cannot exceed 16 for
TRACKPACK/E
only systems and 50 for combined
ARTTRACK5
&
ARTTRACK5/C
and
TRACKPACK/E
systems respectively.
The task of the master is to gather all single data outputs from all slaves and to merge
them into one single data output. The
DTrack2
frontend connects to the master only and
allows to configure (e.g. cameras, output, tracking, etc.) the entire tracking system as
usual.
Z
The master has to be an
ARTTRACK
Controller with "full-featured" li-
cense (<
DTrack2
2.10) and a Synccard2.
Starting with
DTrack2
version v2.10 a new license model has been es-
tablished. The master controller needs to have a dedicated "cascaded
systems" license as well as a sufficient license for ALL cameras in the
cascade, e.g. 4
ARTTRACK5
+ 4
TRACKPACK/E
cameras = license for
8 cameras.
5.4.1 Connecting a cascade
Depending on your setup there are different options how to connect the single tracking
systems within a cascade.
Option 1 - master: all
ART
and
ARTTRACK
Controllers, slave(s):
ART
Controllers
with
TRACKPACK/E
or
TRACKPACK
controllers (discontinued)
Connect the data
output of the slave controller(s) and the one of the master to the same local area network
LAN (e.g. application network, see option 1 in fig. 5.5 on page 67 and fig. 5.6 on page
68).
Option 2 - master:
ART
Controllers (
DTrack2
=> v2.11), slave(s):
ART
Controllers
with
TRACKPACK/E
or
TRACKPACK
controllers (discontinued)
Connect the data
output of the slave controller(s) to the cascaded network port of the master (see option 2
in fig. 5.5 on page 67). Please use a switch for two or more
TRACKPACK
slaves.
Option 3 - master:
ARTTRACK
controllers (discontinued), slave(s):
TRACKPACK
con-
trollers (discontinued)
Connect the data output of the slave controller(s) to the camera
network of the master (see option 3 in fig. 5.6 on page 68).
66
Содержание Flystick3
Страница 220: ...10 General Information 10 4 Declaration of conformity 220 ...
Страница 221: ...10 4 Declaration of conformity 221 ...
Страница 222: ...10 General Information 222 ...
Страница 223: ...10 4 Declaration of conformity 223 ...
Страница 224: ...10 General Information 224 ...
Страница 233: ...10 4 Declaration of conformity 233 ...
Страница 234: ...10 General Information 234 ...
Страница 235: ...Appendix 10 4 Declaration of conformity 235 ...
Страница 248: ...A Technical specifications ARTTRACK2 discontinued ARTTRACK3 discontinued TRACKPACK discontinued 248 ...
Страница 249: ...Appendix A A 7 System latency TRACKPACK Cascade discontinued 249 ...
Страница 269: ...Appendix B B 3 Input of Special Control Data via Ethernet tfb 2 0 0 1 0 0 5 0 1 0 8 0 5 269 ...