9 Frequently asked questions (FAQ)
Synchronization failed in
ARTTRACK5
&
TRACKPACK/E
systems
Due to the single cable solution, the camera is both powered and synchronized over Eth-
ernet. There is no need to guide or check additional cables dedicated to synchronisation
of the cameras. Still hardware issues regarding the controller can arise when using ex-
ternal trigger units, e.g. projectors or graphics cards.
1. Check the cabling (hardware issue):
•
Please make sure that the coaxial cables are not damaged.
•
Take care of using the correct ports:
–
EXT.In: input of the external synchronization
•
Active stereo
: when using external synchronization (video) the correct cabling
would look as follows:
•
Active stereo
: when using external synchronization (TTL) the correct cabling
would look as follows:
2. Check the synchronization settings (software issue):
•
Go to
Settings
→
Synccard
and double-check the settings (external video sig-
nal or TTL) for the Synccard.
•
In case of external synchronization, please make sure that the synchronization
signal is being sent by the external source.
Synchronization failed in cascaded systems
Cascading means that two or more stand-alone tracking systems are combined to one
large system in order to have only one consolidated data output. Therefore, the system
is subdivided into one master and up to eight slaves.
The task of the master is to synchronize all slave controllers attached and gather all single
data outputs from all slaves and to merge them into one single data output.
Please refer to chapter 5.4 on page 66.
196
Содержание Flystick3
Страница 220: ...10 General Information 10 4 Declaration of conformity 220 ...
Страница 221: ...10 4 Declaration of conformity 221 ...
Страница 222: ...10 General Information 222 ...
Страница 223: ...10 4 Declaration of conformity 223 ...
Страница 224: ...10 General Information 224 ...
Страница 233: ...10 4 Declaration of conformity 233 ...
Страница 234: ...10 General Information 234 ...
Страница 235: ...Appendix 10 4 Declaration of conformity 235 ...
Страница 248: ...A Technical specifications ARTTRACK2 discontinued ARTTRACK3 discontinued TRACKPACK discontinued 248 ...
Страница 249: ...Appendix A A 7 System latency TRACKPACK Cascade discontinued 249 ...
Страница 269: ...Appendix B B 3 Input of Special Control Data via Ethernet tfb 2 0 0 1 0 0 5 0 1 0 8 0 5 269 ...