Chapter
6
6.5 Measurement Tool
In this dialogue you can define the ’
number of Measurement Tools
’ as well as ’
number of
references
’. Additionally several other parameters can be changed to suit your applica-
tion.
Control
Description
number of Measurement Tools
configure the number of devices to be used
number of references
configure the number of reference bodies to be used
use old output format
configure legacy output format (refer to chapter
B.2.9 on page 265
measurement duration [s]
configure the time to perform a measurement with
the Measurement Tool (valid range: 0.2 - 10.0 sec)
tool tip tolerance [mm]
specify the range within which the tip is assumed to
be static (valid range: 0.1 - 5.0 mm)
activate measurement start simulation
activate the gesture detection and enable the re-
spective controls
minimal angular variation [deg]
specify the minimum angle that the Measurement
Tool has to be tilted over to start a measurement
(valid range: 10
◦
- 120
◦
)
maximum lead time for this angular
variation [s]
waiting time before the measurement start after ges-
ture detection
Table 6.9: Measurement Tool settings
References
If you are working with a reference body you may assign it to a specific
’
Measurement Tool ID
’:
•
mark the respective Measurement Tool ,
•
mark the reference body and
•
press
Select
.
Repeat these steps if you want to assign references to other Measurement Tools .
Measurement Duration
It is possible to define the duration of a point measurement. A
compromise has to be found between the amount of data collected and the convenience
of holding the measurement tool. Enter the value in seconds in the field
measurement
duration [s]
.
Tool Tip Tolerance
The tracking system will take measurements up to a defined jitter in
millimeter around the tool tip. Configure this tolerance to suit your application. Enter the
value in millimeters in
tool tip tolerance [mm]
.
Start Simulation
In certain applications and use cases it might be more convenient to
start the measurement by a gesture rather than pressing a button on your PC. Tick the
103
Содержание Flystick3
Страница 220: ...10 General Information 10 4 Declaration of conformity 220 ...
Страница 221: ...10 4 Declaration of conformity 221 ...
Страница 222: ...10 General Information 222 ...
Страница 223: ...10 4 Declaration of conformity 223 ...
Страница 224: ...10 General Information 224 ...
Страница 233: ...10 4 Declaration of conformity 233 ...
Страница 234: ...10 General Information 234 ...
Страница 235: ...Appendix 10 4 Declaration of conformity 235 ...
Страница 248: ...A Technical specifications ARTTRACK2 discontinued ARTTRACK3 discontinued TRACKPACK discontinued 248 ...
Страница 249: ...Appendix A A 7 System latency TRACKPACK Cascade discontinued 249 ...
Страница 269: ...Appendix B B 3 Input of Special Control Data via Ethernet tfb 2 0 0 1 0 0 5 0 1 0 8 0 5 269 ...