6 Interaction devices
checkbox
activate measurement start simulation
to enable the gesture detection. The
gesture is simply tilting the the Measurement Tool along the tip axis similar to waving. You
can configure the minimum angle of tilt that is necessary to detect the gesture. Enter the
value in
◦
[deg] in the field
minimal angular variation [deg]
. Additionally you can specify a
waiting time until the measurement starts after detection of the gesture. Specify the time
in seconds in the field
maximum lead time for this angular variation [s]
.
6.5.1.1 Measurement Tool Calibration
The calibration of the Measurement Tool is separated into two steps:
1. body calibration of the Measurement Tool and
2. calibration of the tip.
Body Calibration
First, please calibrate the Measurement Tool with a standard body
calibration (see chapter 8.6.5.2 on page 177) by selecting
Calibration
→
Body
. In the up-
coming dialogue the body to be selected is named ’
Measurement Tool body 01
’. Please
define the orientation of the body coordinate system relative to the body (default setting
is due to body). Make sure that all markers of the Measurement Tool are seen by the
cameras using the Monitor 2DOF display which appears in the background.
If you are working with a reference body you would have to calibrate it as well. This is also
done by a standard body calibration. Just select the body named ’
Measurement Tool ref-
erence body 01
’.
Press "Calibrate" and the calibration starts within 5 seconds.
Tip calibration
After a successful body calibration, you have to calibrate the tip of the
Measurement Tool by selecting
Calibration
→
Measurement Tool
(see figure 6.28 on
page 104) .
Figure 6.28: Measurement Tool Tip Calibration
Place the Measurement Tool in front of the cameras with the tip fixed at exactly one position
(e.g. on a hard surface). Press
Calibrate
to start the calibration process. Gently move
104
Содержание Flystick3
Страница 220: ...10 General Information 10 4 Declaration of conformity 220 ...
Страница 221: ...10 4 Declaration of conformity 221 ...
Страница 222: ...10 General Information 222 ...
Страница 223: ...10 4 Declaration of conformity 223 ...
Страница 224: ...10 General Information 224 ...
Страница 233: ...10 4 Declaration of conformity 233 ...
Страница 234: ...10 General Information 234 ...
Страница 235: ...Appendix 10 4 Declaration of conformity 235 ...
Страница 248: ...A Technical specifications ARTTRACK2 discontinued ARTTRACK3 discontinued TRACKPACK discontinued 248 ...
Страница 249: ...Appendix A A 7 System latency TRACKPACK Cascade discontinued 249 ...
Страница 269: ...Appendix B B 3 Input of Special Control Data via Ethernet tfb 2 0 0 1 0 0 5 0 1 0 8 0 5 269 ...