Chapter
8
8.5 Menu Settings
Info / Action
Description
number of bod-
ies
Increase / Decrease the number of accessible slots (i.e. body IDs) for
calibration of targets.
ID
The targets are sorted in ascending order (i.e. increasing body ID).
Active
Activate or deactivate a target by ticking. Data of deactivated targets
will not be transmitted in the data stream. The target sequence will not
be affected.
Name
Change the name of a target by clicking. The target sequence will not
be affected.
Model
Additional info about the model of an optionally assigned inertial sensor.
Device ID
The device ID of an optionally assigned inertial sensor.
Calibration
Provides information about the target calibration status.
Filter
Deactivate the filtering of tracking data for each target, filtering is acti-
vated by default. A detailed description of the filtering options can be
found in chapter 8.5.6.1 on page 158.
Delete
Delete the calibration data of a target - effective immediately after con-
firming the query. The target sequence will not be affected.
Reset
Reset the calibration to predefined ’
Target Library
’ values, in case the
geometry has been re-calibrated by the user manually after inital cali-
bration via the ’
Target Library
’ function.
Change order
With the arrows on the right-hand side of the window you may re-
arrange the order of the targets. The data output will change accord-
ingly.
Table 8.11: Body Administration - Detailed description
i
The maximum number of bodies depends on your license and includes
ALL calibrated interaction devices (e.g. 4 body license: 1 standard
body + 1 set of Fingertracking (left + right) + 1 Flystick). Hybrid targets
are listed as standard bodies, with additional info about the model of
the inertial sensor and its device ID.
The column
Calibration
(see figure 8.16 on page 156) provides information about the tar-
get calibration status:
•
’
not calibrated
’ means that a customized target has not been calibrated yet.
•
’
Target Library
’ means that the predefined calibration file from the system is being
used.
•
’
Target Library, re-calibrated
’ means that the predefined calibration file has been
used, but the geometry has been re-calibrated manually.
•
’
Custom
’ means that a manual body calibration has been performed.
•
’
Optical
’ means that an inertial sensor has been disassociated from a fully calibrated
hybrid body .
•
’
Full
’ means that a hybrid body calibration has been performed or that predefined
calibration data stored inside the hybrid inertial sensors is being used.
157
Содержание Flystick3
Страница 220: ...10 General Information 10 4 Declaration of conformity 220 ...
Страница 221: ...10 4 Declaration of conformity 221 ...
Страница 222: ...10 General Information 222 ...
Страница 223: ...10 4 Declaration of conformity 223 ...
Страница 224: ...10 General Information 224 ...
Страница 233: ...10 4 Declaration of conformity 233 ...
Страница 234: ...10 General Information 234 ...
Страница 235: ...Appendix 10 4 Declaration of conformity 235 ...
Страница 248: ...A Technical specifications ARTTRACK2 discontinued ARTTRACK3 discontinued TRACKPACK discontinued 248 ...
Страница 249: ...Appendix A A 7 System latency TRACKPACK Cascade discontinued 249 ...
Страница 269: ...Appendix B B 3 Input of Special Control Data via Ethernet tfb 2 0 0 1 0 0 5 0 1 0 8 0 5 269 ...