A Technical specifications
Operating temperature
0 .. 38
◦
C
Relative humidity
5 .. 50%, non-condensing
Hazard notes for service personnel:
Risk of explosion if the mainboard battery is incorrectly replaced. Re-
place only with the same or from manufacturer recommended similar
type.
In order to replace a main fuse of the
ART
Controller always unplug the
power cord. Two main fuses are existing since two power supplies are
installed. So the device is possibly still under power although a fuse
has blown.
A.6 Overall system
System parameters
number of cameras
2 - 50 (max. 16 for
TRACKPACK/E
and
TRACKPACK
systems
(discontinued)
max. number of targets
50
max. number of hands
4
max. number of Flysticks
- Flystick2
5
- Flystick3
1
Scalability
ARTTRACK
system: fully scalable (2 - 50 cameras)
TRACKPACK/E
and
TRACKPACK
systems (discontinued):
cascadable up to 16 cameras (additional controller necessary)
Accuracy
- of the timestamp
with a Synccard2/3:
∆
t
err
∼ ±
0
.
01
ms
with a SynccardTP:
∆
t
err
∼ ±
0
.
5
ms
with a 3-Space wired inertial sensor:
∆
t
err
∼ ±
0
.
1
ms
Operating conditions
Temperature
0 .. 38
◦
C
Relative humidity
5 .. 50%, non-condensing
Compatible shutter glasses
NuVision APG6000
×
NuVision APG6100
×
NVidia 3D Vision Pro
×
, radio synchronization
RealD CE1
×
RealD CE2
×
RealD CE3
×
RealD CE4
-
RealD CE5
×
Volfoni EDGE
×
, with Volfoni or NuVision Long-Range Emitter
XPand X103
×
, with NuVision Long-Range Emitter
XPand X101
×
244
Содержание Flystick3
Страница 220: ...10 General Information 10 4 Declaration of conformity 220 ...
Страница 221: ...10 4 Declaration of conformity 221 ...
Страница 222: ...10 General Information 222 ...
Страница 223: ...10 4 Declaration of conformity 223 ...
Страница 224: ...10 General Information 224 ...
Страница 233: ...10 4 Declaration of conformity 233 ...
Страница 234: ...10 General Information 234 ...
Страница 235: ...Appendix 10 4 Declaration of conformity 235 ...
Страница 248: ...A Technical specifications ARTTRACK2 discontinued ARTTRACK3 discontinued TRACKPACK discontinued 248 ...
Страница 249: ...Appendix A A 7 System latency TRACKPACK Cascade discontinued 249 ...
Страница 269: ...Appendix B B 3 Input of Special Control Data via Ethernet tfb 2 0 0 1 0 0 5 0 1 0 8 0 5 269 ...