Chapter
8
8.2 Connecting to the controller
Scan LAN
To scan your LAN simply select
Scan
followed by pressing
Update list
. You
will see a list of all controllers in your network. Controllers set in grey are used by other
remote PCs in your network (
→
IP address listed at the bottom of the welcome screen),
whereas available controllers for connection are set in black. If not, please refer to chap-
ter 9 on page 192. You can easily identify your controller by comparing the serial number
(e.g. 301422021 listed in column
Serial
) with the corresponding one on its label (back of
the
ART
controller, refer to 5.2 on page 55). You can also sort the list by host-name
Name
or IP-addresses
IP
. Select the appropriate entry of your controller and press
Connect
.
i
If the Controller is not connected via an ethernet cable or no DHCP
server is running, it will use its fall-back IP address (IP 192.168.0.1,
subnet mask 255.255.255.0)
(a) specific controller
(b) scan the network
Figure 8.2: Controller Selection
8.2.2 Setting a static IP address inside
DTrack2
If necessary you can set your controller to a static IP address using the following steps:
•
start up
DTrack2
and connect to your controller by pressing
Connect
•
select the menu
Settings
→
Controller
•
untick the checkbox
DHCP client
•
enter
IP address
and
subnet mask
•
optionally, enter
gateway
and
nameserver
•
reboot the controller for the changes to take effect
Z
Please note that these settings are not part of your personal configura-
tion. Changes in this menu will affect all users of your controller! Your
controller may become unreachable with wrong IP settings! Refer to
chapter 8.2.4 on page 127).
In case you need to specify a static IP address without using the frontend (e.g. installation
on network without DHCP service available) please refer to chapter 8.2.4 on page 127
instead.
125
Содержание Flystick3
Страница 220: ...10 General Information 10 4 Declaration of conformity 220 ...
Страница 221: ...10 4 Declaration of conformity 221 ...
Страница 222: ...10 General Information 222 ...
Страница 223: ...10 4 Declaration of conformity 223 ...
Страница 224: ...10 General Information 224 ...
Страница 233: ...10 4 Declaration of conformity 233 ...
Страница 234: ...10 General Information 234 ...
Страница 235: ...Appendix 10 4 Declaration of conformity 235 ...
Страница 248: ...A Technical specifications ARTTRACK2 discontinued ARTTRACK3 discontinued TRACKPACK discontinued 248 ...
Страница 249: ...Appendix A A 7 System latency TRACKPACK Cascade discontinued 249 ...
Страница 269: ...Appendix B B 3 Input of Special Control Data via Ethernet tfb 2 0 0 1 0 0 5 0 1 0 8 0 5 269 ...