CLK_CTRL_SEL Register
The CLK_CTRL_SEL Register characteristics are:
Purpose
Controls the clock select multiplexers.
Usage constraints
There are no usage constraints.
Memory offset and full register reset value
See
.
The following table shows the CLK_CTRL_SEL Register bit assignments.
Table 3-68 CLK_CTRL_SEL Register bit assignments
Bits
Name
Function
[31:13] -
Reserved.
[12]
CTRL_PLL_MUX_CLK_SEL
Select PLL MUX input:
0b0
: PLL0
0b1
: Not used
Reset value
0b0
.
3 Programmers model
3.11 Serial Configuration Control registers
101835_0000_01_en
Copyright © 2019, 2020 Arm Limited or its affiliates. All rights
reserved.
3-128