CTRL_ENABLE Register
The CTRL_ENABLE Register characteristics are:
Purpose
Individually enables or disables the nine PVT sensors.
Usage constraints
There are no usage constraints.
Memory offset and full register reset value
See
3.9.1 PVT sensor control registers summary
.
The following table shows the CTRL_ENABLE Register bit assignments.
Table 3-53 CTRL_ENABLE Register bit assignments
Bits
Name
Function
[31:3]
-
Reserved.
[2:0]
CTRL_ENABLE[2:0]
PVT sensors Enable input:
0b0
: Not enabled.
0b1
: Enabled.
Reset value
0x000
.
CTRL_AUTOCLEAR Register
The CTRL_AUTOCLEAR Register characteristics are:
Purpose
Individually enables the nine PVT sensors autoclear functions.
Usage constraints
There are no usage constraints.
Memory offset and full register reset value
See
3.9.1 PVT sensor control registers summary
.
The following table shows the CTRL_AUTOCLEAR Register bit assignments.
Table 3-54 CTRL_AUTOCLEAR Register bit assignments
Bits
Name
Function
[31:3]
-
Reserved.
[2:0]
CTRL_AUTOCLEAR[2:0]
Enable or disable PVT sensors autoclear
functions:
0b0
: Not enabled.
0b1
: Enabled.
Reset value
0x1FF
.
CTRL_CLKSEL Register
The CTRL_CLKSEL Register characteristics are:
Purpose
Individually selects the nine PVT sensors input clocks.
3 Programmers model
3.9 PVT sensor registers
101835_0000_01_en
Copyright © 2019, 2020 Arm Limited or its affiliates. All rights
reserved.
3-115