Wireless keypad PU-R
7 strelec’s control
57
When a device is in the normal state, the label “norm”
1
will be displayed in all the
lines. Other possible labels are the following:
Line
Label
Fault correctness
State
BROKEN
Restore the normal status of the detector
1
(close window and doors; leave the detector
zone of an infra red detector, etc.)
FIRE!
Eliminate the fire alarm cause. Reset a fire
alarm (the paragraph 7.7, page 61).
BYPASS!
The detector is bypassed. Turn bypass of the
detector off (the paragraph 7.10, page 63)
manually or disarm the partition to reset
forced bypass.
FAULT!
Define a fault, having reviewed an event pro-
tocol (the paragraph 7.4, page 58).
Eliminate the fault or substitute the device.
After the fault has been fixed, reset the fault
(the paragraph 7.7, page 61).
RF link
FAULT!
Define the reason of zero communication. The
device should be turned on and stay within the
zone of radio-visibility. Evaluate communica-
tion quality with the device (the paragraph 5.7,
page 43), which should be not worse than
"4"
(good)
. Reset a fault after the reasons caused
lack of communication have been fixed (the
paragraph 7.7, page 61).
Case
TAMPERED!
Close the device’s cover
1
.
Reset a fault (the paragraph 7.7, page 61).
Primary
battery
FAULT!
Replace a primary battery
1
.
Reset a fault (the paragraph 7.7, page 61).
Secondary
battery
FAULT!
Replace a secondary battery
1
.
Reset a fault (the paragraph 7.7, page 61).
1
A change of a device’s status into the status “norm” after a fault or tamper has been eliminated, is indicated after
its period of wireless signals transmission is expired (by default – 32 сек).