Wireless keypad PU-R
77
►Properties of the auto dialer UOO-AV (version 1)
Telephone numbers 1-4
– telephone numbers of the Monitoring Sta-
tion’s telephone lines.
The telephone numbers can include numbers from 0 to 9, as well as
symbols: ‘t’ and ‘p’.
The symbol ‘t’ means that a dialer,
while dialing, should wait a beep,
whereas the symbol ‘p’ – a 2-second
pause should be hold.
In order to dial the symbols ‘t’ or ‘p’
in a telephone number, press the but-
ton
‹ ›
while being in the needed position of the number.
Transmission format
– a protocol of data transmission to the receiver
of the Monitoring Station.
UOO-АV
(version 1) supports
two types of data transmission protocols
such as "Ademco Contact ID" and "ЧM Argus-T".
Additional information
Specification of PU-R
Dimensions – 130x145x30 mm
Weight – not more than 0.3 kg
Range of operating temperatures – -10..+55° С
Relative humidity during operation – up to 93 % at 40° С
Temperature range during transportation – -50..+55° С
Relative humidity during transportation – up to 95 % at 40° С
Protection index – IP41
Mean time between failures – at least 60000 hours
Mean service life (regardless battery life) – at least 8 years
1 telephone number
9 t 8 _
Change
OK