Wireless keypad PU-R
76
►Properties of OM-R, versions 1 and 2
Control of input Flt – if control is on, a fault signal (“Fault”) is trans-
ferred to the wireless expander, when load resistance connected to the
input “Flt”, reaches some high values. Resistance thresholds are the fol-
lowing:
Resistance at the input Flt OM-R state
More than 10 kOhm
fault
From 4 to 7 kOhm
norm
Less than 2.8 kOhm
fault
Type
– selection of relay triggering type from the following list:
Normally-closed
Normally-opened
pulsed (about 4 sec.)
periodical swi normally-opened (the period is 2 sec.)
Power supply monitoring – is this option is on,
OM-R
monitors its pow-
er supply voltage
OM-R’s power supply voltage OM-R state
More than 23 V
Norm
from 15 to 22 V
fault
from 12 to 15 V
norm
Less than 11 V
fault
8.8
Properties of system devices
The properties required to be configured while adding a device, are written
in
bold
.
►Common
The common properties of the wireless alarm system “
Argon
” and the auto
dialer
UOO-AV
(version 1).
Address
– a cover address of the messages transmission system to the
Monitoring Station.
Transmission period – a transmission period of control signals varied
from 2 min to 24 hours, to the Monitoring station.