Wireless keypad PU-R
69
disarming
Event of WEx
– influence of the wireless expander’s own events (case’s
tampering and power supply’s fault) to the relay.
Influence of partitions
– connection of events occurred in the partitions
of the wireless expander with the relay.
Operation time – an option, with enables to restrict time of a relay opera-
tion up to 8 min. This option can be useful, for example, to restrict oper-
ation time of an external sounder.
Type
– selection of a relay’s triggering type from the list:
Normally-closed;
Normally-opened;
Pulsed (single closing for 4 sec.);
Periodically-sw normally-opened (the period is 2 sec.)
Periodically-sw normally-closed (the period is 2 sec.)
Delay – a delay of a relay’s activation from 3 sec. to 4 min.
►User (1-30)
Partitions
– a list of wireless expander’s local partitions, which is con-
trolled by a user from the local keypads
PUL
or
PUL-R
.
Code
– a user’s code, which is used for controlling of wireless expand-
er’s partitions by
PUL
or
PUL-R
.
►Interface properties of the detection circuit "Akkord-512"
The options are included into the system’s common properties( see the para-
graph 4.4 menu "Properties").
Initial address of SL512
– an initial address, displaying status of Strelec’s
wireless expanders in the detection circuit of the Control Panel "Akkord-
512", varies from 0 to 62 (enter 64 in order to turn the displaying mode off).
Every expander of the system occupies 2 addresses in the detection circuit
SL “Akkord-512". Concurrently, the partitions 1-8 of the wireless expander
occupies address with the number i in the SL, whereas the partitions 9-16
occupy the address with the number i+1.
For example:
Initial address = 34.