UG-549
ADuCM310 Hardware Reference Manual
Rev. C | Page 152 of 192
REGISTER SUMMARY: UART
Table 213. UART Register Summary
Address
Name
Description
Reset
Access
0x40005000
COMTX
Transmit holding register
0x0000
W
0x40005000
COMRX
Receive buffer register
0x0000
R
0x40005004
COMIEN
Interrupt enable register
0x0000
RW
0x40005008
COMIIR
Interrupt identification register
0x0001
RC
0x4000500C
COMLCR
Line control register
0x0000
RW
0x40005010
COMMCR
Modem control register
0x0000
RW
0x40005014
COMLSR
Line status register
0x0060
RC
0x40005018
COMMSR
Modem status register
0x0000
RC
0x4000501C
COMSCR
Scratch buffer register
0x0000
RW
0x40005024
COMFBR
Fractional baud rate register
0x0000
RW
0x40005028
COMDIV
Baud rate divider register
0x0001
RW
REGISTER DETAILS: UART
Transmit Holding Register
Address: 0x40005000, Reset: 0x0000, Name: COMTX
COMRX and COMTX share the same address while they are implemented as different registers. If these registers are written to, the user
accesses the transmit holding register (COMTX). If these registers are read from, the user accesses the receive buffer register (COMRX).
Table 214. Bit Descriptions for COMTX
Bits
Bit Name
Description
Reset
Access
[15:8]
RESERVED
Reserved.
0x0
R
[7:0]
THR
Transmit holding register. This is an 8-bit register to which the user can
write the data to be sent. If the ETBEI bit is set in the COMIEN register, an
interrupt is generated when COMTX is empty. If user code sets ETBEI while
COMTX is already empty, an interrupt is generated immediately.
0x0
W
Receive Buffer Register
Address: 0x40005000, Reset: 0x0000, Name: COMRX
Table 215. Bit Descriptions for COMRX
Bits
Bit Name
Description
Reset
Access
[15:8]
RESERVED
Reserved.
0x0
R
[7:0]
RBR
Receive buffer register. This is an 8-bit register from which the user can
read received data. If the ERBFI bit is set in the COMIEN register, an interrupt is
generated when this register is fully loaded with the received data via the
serial input port. If user code sets the ERBFI bit while COMRX is already full,
an interrupt is generated immediately.
0x0