Configuring Communication
62
CV17 17" Modero Coor Video Touch Panels
5.
Click on the
NetLinx Master
radio button (
from the Platform Selection section
) to indicate that you are
working as a NetLinx Master.
6.
Click on the
Virtual Master
radio box (
from the Transport Connection Option section
) to indicate you
are wanting to configure the PC to communicate directly with a panel. Everything else such as the
Authentication is greyed-out because you are not going through the Master’s UI.
7.
Click the
Edit Settings
button (
on the Communications Settings dialog
) to open the Virtual NetLinx
Master Settings dialog (FIG. 58).
8.
From within this dialog enter the System number (
default is 1
) and note the IP Address of the target PC
being used as the Virtual Master. This IP Address can also be obtained by following these procedures:
On your PC, click
Start
>
Run
to open the Run dialog.
Enter
cmd
into the Open field and click
OK
to open the command DOS prompt.
From the
C:\>
command line, enter
ipconfig
to display the IP Address of the PC. This information
is entered into the
Master IP/URL
field on the panel.
9.
Click
OK
three times to close the open dialogs, save your settings, and return to the main NetLinx Studio
application.
10.
Click the
OnLine Tree
tab in the Workspace window to view the devices on the Virtual System.
The
default System value is one
.
11.
Right-click on the
Empty Device Tree/System
entry and select
Refresh System
to re-populate the list.
12.
Power-up your panel and press and hold the grey Front Setup Access button (
for 3 seconds
) to continue
with the setup process and proceed to the Setup page.
13.
Select
Protected Setup
>
System Connection
(located on the lower-left) to open the System Connection
page (FIG. 59).
14.
Press the blue
ICSNET/Ethernet
field (
from the Master Connection section
) until the choices cycle to the
word
Ethernet.
15.
Press the
Mode
field until the choices cycle to the word
URL
.
By selecting
URL
, the System Number field becomes read-only (grey) because the panel pulls this
value directly from the communicating target Master (virtual or not). A virtual Master system value
can be set within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.
16.
Press the
Master IP/URL
field to open a Keyboard and enter the IP Address of the PC used as the Virtual
Master.
17.
Click
Done
to accept the new value and return to the System Connection page.
18.
Do not alter the Master Port Number value (
this is the default value used by NetLinx
).
19.
Press the
Back
button to open the Protected Setup page.
20.
Press the on-screen
Reboot
button to both save any changes and restart the panel.
FIG. 59
Sample System Connection page (for Virtual Master communication)
Enter the IP Address
information of the PC
used as a Virtual
Master
The System Number is
assigned to the Virtual
Master within the AMX
software application
(these must match)
Содержание modero NXD-CV17
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV17 17 Modero Touch Panel Last Revised 8 04 2010...
Страница 10: ...viii CV17 17 Modero Coor Video Touch Panels Table of Contents...
Страница 56: ...Installation 46 CV17 17 Modero Coor Video Touch Panels...
Страница 86: ...Upgrading Modero Firmware 76 CV17 17 Modero Coor Video Touch Panels...
Страница 162: ...Appendix 152 CV17 17 Modero Coor Video Touch Panels...
Страница 167: ...Troubleshooting 157 CV17 17 Modero Coor Video Touch Panels...