Upgrading Modero Firmware
71
CV17 17" Modero Coor Video Touch Panels
Preparing the panel for communication via an IP
1.
Press the
Connection Type
field (
from the Master Connection section
) until the choices cycle to the word
Ethernet
.
2.
Press the blue
Mode
field until the choices cycle to the word
URL
.
By selecting
URL
, the System Number field becomes read-only (grey) because the panel pulls this value
directly from the communicating target Master (virtual or not). A virtual Master system value can be set
within the active AMX software applications such as: NetLinx Studio, TPD4, or IREdit.
3.
Press the blue
Master IP/URL
field to open a Keyboard and enter the NetLinx Master’s
IP Address
(obtained from the Diagnostics - Networking Address dialog of the NetLinx Studio
application)
.
4.
Click
Done
to accept the new value and return to the System Configuration page.
5.
Do not alter the Master Port Number value (
this is the default value used by NetLinx
).
6.
Press the on-screen
Reboot
button, from the Protected Setup page, to restart the panel and save any
changes.
Verifying and Upgrading the panel firmware via an IP
1.
Click the
OnLine Tree
tab in the Workspace window to view the devices on the System.
The default
System value is one.
2.
Right-click the associated System number (from the Workspace window) and select
Refresh System
to
detect of all devices on the current system, establish a new connection to the Master, and refresh the
System list with devices on that system.
3.
After the Communication Verification dialog window verifies active communication between the PC and
the Master, verify the panel appears in the
OnLine Tree
tab of the Workspace window (FIG. 67).
The
default Modero panel value is 10001
.
4.
If the panel firmware version is not the latest available; locate the latest firmware file from the
www.amx.com
>
Tech Center
>
Downloadable Files
>
Firmware Files
>
Modero Panels
section of
the website.
5.
Download the appropriate KIT file to your computer.
6.
Verify you have downloaded the latest Modero firmware (KIT) file to a known location.
7.
Select
Tools
>
Firmware Transfers > Send to NetLinx Device
from the Main menu to open the Send to
NetLinx Device dialog (FIG. 68). Verify the panel’s System and Device number
values match those
values listed within the System folder in the
OnLine Tree
tab of the Workspace window.
FIG. 67
NetLinx Workspace window (showing connected Modero panel)
Showing a Master
firmware version and
device number
Showing the current Modero
panel firmware version and
device number
Shows NetLinx Studio
version number
The panel firmware is shown on the right of the listed panel. New G4 firmware
features are available with firmware beginning with v2.XX.
Содержание modero NXD-CV17
Страница 1: ...Operation Reference Guide Touch Panels NXT D CV17 17 Modero Touch Panel Last Revised 8 04 2010...
Страница 10: ...viii CV17 17 Modero Coor Video Touch Panels Table of Contents...
Страница 56: ...Installation 46 CV17 17 Modero Coor Video Touch Panels...
Страница 86: ...Upgrading Modero Firmware 76 CV17 17 Modero Coor Video Touch Panels...
Страница 162: ...Appendix 152 CV17 17 Modero Coor Video Touch Panels...
Страница 167: ...Troubleshooting 157 CV17 17 Modero Coor Video Touch Panels...